Understanding the Pentair IntelliChlor Salt Chlorine Generator
Pentair designed the IntelliChlor as a user-friendly salt electrolyser‚ prioritizing both compact technology and reliable service for pool sanitation needs.
What is the Pentair IntelliChlor?
The Pentair IntelliChlor is a salt chlorine generator (SCG) designed to automatically produce chlorine for your swimming pool‚ offering a more convenient and comfortable alternative to traditional chlorine methods. It utilizes a process called electrolysis to convert salt into chlorine‚ eliminating the need for constant purchasing‚ handling‚ and adding chlorine tablets or liquid.
This system aims for simplicity and reliability‚ featuring compact technology for easy installation and operation. Pentair focused on creating a system that minimizes maintenance while consistently delivering sanitized pool water. The IntelliChlor models‚ including PLUS‚ LT‚ IC20‚ and IC40‚ cater to various pool sizes and needs‚ providing efficient and effective sanitation. It’s a key component for automated pool systems‚ seamlessly integrating with Pentair automation systems for complete control.
Key Features and Benefits
The Pentair IntelliChlor boasts several key features‚ including automatic chlorine generation‚ reducing chemical handling and costs. Its intelligent operation optimizes performance‚ while the optional optical pen provides advanced monitoring capabilities. A significant benefit is consistent water quality‚ eliminating chlorine odors and irritation;
Furthermore‚ the IntelliChlor simplifies pool maintenance with features like self-diagnostics and easy-to-read displays. Integration with Pentair automation systems allows for remote control and monitoring. The system’s reliability and compact design contribute to long-term value. Users experience a more enjoyable swimming experience with softer‚ silkier water‚ free from harsh chemicals‚ making it a superior sanitation solution.

Installation Process
Installation involves initial setup‚ making connections‚ and integrating with Pentair automation systems‚ as detailed in the provided installation and users guide.
Initial Setup and Connections
Before beginning‚ carefully review the IntelliChlor Plus or LT Installation and Users Guide for detailed instructions specific to your model. Proper setup is crucial for optimal performance and longevity. The initial phase involves physically mounting the Power Center and Salt Cell‚ ensuring adequate ventilation and proximity to the filtration system.
Connections require careful attention to plumbing‚ ensuring proper flow direction as indicated on the cell housing. Electrical connections must adhere to local codes and utilize appropriate wiring sizes‚ as outlined in the IntelliChlor Power Center Installation Guide. Connecting the system to the pool’s filtration system is a vital step‚ guaranteeing water passes through the salt cell for effective chlorination.
Always verify all connections are secure and watertight before proceeding to power up the system.
Connecting to Pentair Automation Systems
Seamless integration with Pentair automation systems enhances control and convenience. The IntelliChlor Salt Chlorine Generator is designed to communicate effectively with compatible Pentair systems‚ allowing for remote monitoring and adjustment of chlorine output levels. This connectivity streamlines pool management‚ offering features like scheduling and automated responses to water conditions.
The installation guide details the specific communication protocols and wiring requirements for connecting the IntelliChlor to systems like IntelliCenter or IntelliTouch. Proper configuration within the automation system’s interface is essential to enable full functionality. Ensure the system recognizes the IntelliChlor and allows for control of its settings.
Successful integration provides a centralized hub for managing all pool functions‚ simplifying maintenance and optimizing water chemistry.
AC Wiring Instructions for IntelliChlor
Proper AC wiring is crucial for the safe and effective operation of the IntelliChlor salt chlorine generator. The IntelliChlor Power Center installation guide provides detailed instructions‚ emphasizing adherence to all local electrical codes. Typically‚ a dedicated circuit is recommended to prevent interference from other appliances.
Wiring generally involves connecting the power supply to designated terminals within the Power Center‚ ensuring correct polarity. When used with an IntelliFlo pump or a 2-speed pump‚ specific wiring configurations may apply‚ as outlined in the manual. Always disconnect power at the breaker before commencing any wiring work.
Qualified electricians should perform the installation to guarantee compliance and safety. Incorrect wiring can lead to equipment damage or pose an electrical hazard.

Troubleshooting Common Issues
Common issues include flashing lights indicating sensor faults or calibration needs‚ and a sanitizer output light flashing at 100‚ requiring a system reset.
Flashing Lights and Their Meanings
Understanding the IntelliChlor’s light patterns is crucial for diagnosing issues. A flashing sanitizer output light at 100 typically signals a sensor or calibration fault‚ often requiring a power cycle to reset the system.
If no lights are displayed‚ it suggests a potential power supply problem or internal component failure‚ necessitating a check of the electrical connections and potentially contacting Pentair tech support.
Refer to the IntelliChlor’s installation and user guide for a comprehensive list of flashing light codes and their corresponding meanings. Pentair provides detailed troubleshooting guides on their website‚ offering quick reference for common issues related to salt cell maintenance and overall system performance. Always consult the manual for specific error interpretations.
Sanitizer Output Light Flashing at 100
When the sanitizer output light on your Pentair IntelliChlor IC40 flashes at 100‚ it generally indicates a sensor fault or a calibration issue within the system. The initial step to resolve this is to perform a simple power cycle – completely turn off and then back on the unit.
Following the reset‚ carefully inspect the salt cell for any signs of scale buildup or physical damage. These conditions can significantly affect the accuracy of the output readings.
If the issue persists‚ consulting Pentair’s tech support is recommended for specific troubleshooting instructions tailored to your application and model. Remember to reference your IntelliChlor manual for detailed guidance.
No Lights Displayed on the IntelliChlor
If your Pentair IntelliChlor unit exhibits no lights on the display panel‚ it suggests a potential power supply issue or a complete system failure. Begin by verifying the circuit breaker supplying power to the unit is not tripped and is functioning correctly.
Double-check all electrical connections to ensure they are secure and free from corrosion. If the breaker is fine and connections are solid‚ the problem may lie within the IntelliChlor’s internal components.
In this scenario‚ it’s crucial to contact Pentair’s tech support immediately for assistance. They can provide specific troubleshooting steps or advise on repair options. Do not attempt internal repairs yourself.

Salt Level Calibration
Accurate salt level calibration is vital for optimal performance; if issues arise‚ contact Pentair’s tech support for tailored troubleshooting guidance.
How to Recalibrate the Salt Level
Recalibrating the salt level on your Pentair IntelliChlor isn’t a standard user procedure. The system is designed to automatically measure and adjust based on conductivity. However‚ if you suspect inaccurate readings‚ or the unit is displaying errors related to salt levels‚ attempting a manual recalibration isn’t recommended.
Instead‚ the primary recommendation from Pentair and pool professionals is to directly contact Pentair’s tech support. They possess specific troubleshooting instructions tailored to your IntelliChlor model and can guide you through the appropriate steps. This ensures the process is done correctly and avoids potential damage to the unit.
Attempting to recalibrate without proper guidance could lead to incorrect chlorine generation‚ impacting water chemistry and potentially causing issues with your pool’s sanitation. Relying on expert assistance from Pentair is the safest and most effective approach.
Contacting Pentair Tech Support for Calibration
When facing salt level calibration issues with your Pentair IntelliChlor‚ reaching out to their technical support is crucial. Direct assistance ensures accurate diagnosis and prevents potential system damage. Unfortunately‚ specific contact details weren’t readily available in the provided snippets‚ highlighting the need to visit the official Pentair website.
Navigate to Pentair’s support section‚ typically found under “Customer Support” or “Contact Us.” Look for options like phone support‚ email submission forms‚ or live chat features. Be prepared to provide your IntelliChlor model number (PLUS‚ LT‚ IC20‚ or IC40) and a detailed description of the problem.
Clearly explain any error messages displayed‚ recent system changes‚ and the steps you’ve already taken. Pentair’s experts can then offer tailored guidance for recalibrating the salt level or resolving underlying issues effectively.

Salt Cell Maintenance
Regular inspection of the salt cell is vital; check for scale buildup or any physical damage‚ as these factors directly impact the IntelliChlor’s output readings.
Checking for Scale Buildup
Scale buildup within the salt cell is a common issue affecting the performance of your Pentair IntelliChlor. This buildup‚ often calcium carbonate‚ reduces the cell’s efficiency in generating chlorine. Visually inspect the cell plates regularly – a white‚ chalky residue indicates scale. Reduced chlorine output or a flashing sanitizer light can also signal scale accumulation.
To check‚ carefully remove the cell (after powering down the system‚ of course!). Examine each plate individually. Minor scaling can sometimes be addressed with a diluted muriatic acid solution‚ following Pentair’s specific instructions in the owner’s manual. However‚ severe scaling may require professional cleaning or cell replacement. Consistent water chemistry balance‚ particularly calcium hardness‚ is crucial in preventing future scale formation‚ extending the life of your IntelliChlor’s salt cell.
Identifying Salt Cell Damage
Salt cell damage can significantly impair your Pentair IntelliChlor’s functionality. Inspect the cell for physical cracks or breaks in the cell body – these are immediate indicators of a problem. Examine the plates themselves for signs of corrosion‚ pitting‚ or complete disintegration. Missing or severely eroded plates will drastically reduce chlorine production.
A damaged cell may also exhibit unusual bubbling or sparking during operation (though this is a safety hazard and requires immediate shutdown!). Reduced sanitizer output‚ despite proper salt levels and calibration‚ is another key sign. If you suspect damage‚ do not attempt repairs yourself. Consult the Pentair owner’s manual for guidance and consider contacting a qualified pool technician for assessment and potential cell replacement. Ignoring damage can lead to system failure.
Pentair Salt Cell Maintenance Guides
Pentair provides comprehensive owner’s manuals and troubleshooting guides on their website for IntelliChlor salt cells‚ including the IC20 and IC40 models. These resources detail recommended cleaning procedures and inspection checklists. Regular maintenance‚ as outlined in these guides‚ is crucial for optimal performance and longevity.
The guides emphasize the importance of visual inspections for scale buildup and physical damage. They also offer step-by-step instructions for cell cleaning using a diluted muriatic acid solution (always following strict safety precautions!). Refer to the specific guide corresponding to your IntelliChlor model for detailed instructions and safety warnings. Proper adherence to these guides will help maximize your investment and ensure consistent water sanitation.

Resetting the IntelliChlor
To resolve issues‚ a simple power cycle can reset the system. For more complex problems‚ consult the manual for specific‚ guided manual reset procedures.
Power Cycling the System
Power cycling is often the first step in troubleshooting an IntelliChlor salt chlorine generator. This simple reset can resolve many minor operational glitches. To power cycle‚ completely disconnect the power supply to the unit – locate the circuit breaker controlling the IntelliChlor and switch it to the ‘off’ position.
Wait a full 60 seconds before switching the breaker back ‘on’. This allows the system to fully discharge and reset its internal components. After restoring power‚ allow the IntelliChlor several minutes to restart and recalibrate. Observe the display panel for any error messages or unusual behavior. If the issue persists after power cycling‚ further troubleshooting steps‚ or contacting Pentair tech support‚ may be necessary.
Manual Reset Procedures
While the IntelliChlor often resolves issues with a simple power cycle‚ specific models may require a manual reset procedure. Unfortunately‚ detailed instructions for a dedicated “reset button” are not widely documented‚ and the unit generally relies on power interruption for resetting.
If the display remains unresponsive‚ or lights are absent‚ confirm the power supply is stable and the breaker hasn’t tripped again. If problems continue‚ contacting Pentair’s tech support is crucial‚ as they can provide model-specific guidance. They may walk you through diagnostic steps or determine if the unit requires professional servicing. Avoid attempting complex internal resets without expert assistance‚ as this could void the warranty or cause further damage.

IntelliChlor Models
Pentair offers several IntelliChlor models‚ including the PLUS‚ LT‚ IC20‚ and IC40‚ each designed to cater to varying pool sizes and sanitation demands.
IntelliChlor PLUS
The IntelliChlor PLUS represents a significant advancement in salt chlorine generation technology. This model is designed for larger pools‚ offering enhanced performance and reliability. Installation and user guides detail a straightforward process for connecting the unit to Pentair automation systems‚ simplifying pool management.
It features a more robust cell design‚ capable of handling higher chlorine demands. The IntelliChlor PLUS also boasts advanced diagnostic capabilities‚ providing users with detailed information about system performance. Proper AC wiring‚ as outlined in the installation guide‚ is crucial for safe and efficient operation. Regular maintenance‚ including checking for scale buildup‚ ensures longevity and optimal functionality.

Owners manuals and troubleshooting guides are readily available on the Pentair website‚ offering solutions to common issues and supporting a seamless pool ownership experience.
IntelliChlor LT
The IntelliChlor LT is engineered as a cost-effective salt chlorine generator‚ ideal for smaller to medium-sized pools. Like the PLUS model‚ detailed installation and user guides are available‚ emphasizing easy connection to Pentair automation systems for integrated pool control.
While offering a more streamlined feature set‚ the LT model maintains Pentair’s commitment to reliability and ease of use. Proper AC wiring‚ as detailed in the installation instructions‚ is essential for safe operation. Troubleshooting guides readily available on the Pentair website assist with resolving common issues‚ such as flashing lights or sensor faults.
Regular salt cell maintenance‚ including inspection for scale buildup‚ is crucial for optimal performance. The LT model provides efficient sanitation‚ delivering a consistently clean and enjoyable pool experience.
IntelliChlor IC20 and IC40
The IntelliChlor IC20 and IC40 models represent Pentair’s advanced salt chlorine generators‚ designed for varying pool sizes and chlorine demands. Comprehensive installation and user guides detail the process of connecting these units to Pentair automation systems‚ ensuring seamless integration.
Troubleshooting resources‚ including guides addressing flashing lights and sensor errors‚ are readily accessible on the Pentair website. A flashing sanitizer output light at 100 often signals a calibration fault‚ requiring a power cycle or salt cell inspection.
Regular salt cell maintenance‚ as outlined in Pentair’s manuals‚ is vital for optimal performance. These models offer efficient and reliable sanitation‚ contributing to a consistently clean and inviting pool environment.

Advanced Features
IntelliChlor boasts intelligent operation and offers an optional optical pen for enhanced control and monitoring of pool sanitation levels‚ per the manual.
Optical Pen (Optional)
The IntelliChlor system offers an optional optical pen‚ a valuable tool for precise water chemistry analysis. This pen‚ when used with compatible Pentair automation systems‚ provides accurate readings of key parameters‚ allowing for fine-tuned adjustments to chlorine production.
Instead of relying solely on traditional test kits‚ the optical pen streamlines the testing process‚ delivering quick and reliable results directly to the system’s interface. This feature enhances the IntelliChlor’s intelligent operation‚ ensuring optimal water balance and sanitation. The manual details how to integrate and calibrate the optical pen for maximum accuracy‚ contributing to a consistently clean and healthy swimming environment. It’s a convenient upgrade for users seeking advanced control.
Intelligent Operation
Pentair’s IntelliChlor boasts intelligent operation‚ designed to simplify pool maintenance and maximize efficiency. The system automatically adjusts chlorine generation based on demand‚ responding to factors like sunlight‚ bather load‚ and water temperature. This adaptive technology minimizes chemical usage and ensures consistently sanitized water.
The manual highlights features like automatic cell cleaning‚ which reverses polarity to prevent scale buildup‚ extending the cell’s lifespan. Furthermore‚ diagnostic capabilities alert users to potential issues‚ such as low salt levels or cell damage. This proactive approach‚ combined with compatibility with Pentair automation systems‚ creates a self-regulating system‚ reducing the need for manual intervention and providing peace of mind.

Safety Precautions
Always prioritize electrical safety and proper chemical handling when installing and maintaining the IntelliChlor system‚ following the Pentair manual’s guidelines.
Electrical Safety
Prioritize electrical safety during IntelliChlor installation and maintenance. Pentair’s manual emphasizes disconnecting power before any work on the unit. Ensure all wiring adheres to local and national electrical codes‚ utilizing a qualified electrician if needed.
The IntelliChlor requires proper grounding to prevent electrical shock hazards. Inspect wiring for damage before connecting‚ and never operate the system with frayed or exposed wires.
Avoid using extension cords‚ and ensure the power supply matches the unit’s specifications. Water and electricity are a dangerous combination; keep the IntelliChlor and all electrical components dry. Regularly check connections for corrosion and tightness. Following these precautions will ensure safe operation and prevent potential hazards.
Chemical Handling
Proper chemical handling is crucial when using a Pentair IntelliChlor salt chlorine generator. While the system reduces traditional chlorine use‚ maintaining water balance remains essential. Always follow manufacturer’s instructions for any supplemental chemicals added to the pool.
Never mix different chemicals together‚ as this can create dangerous reactions. Store chemicals in a cool‚ dry‚ well-ventilated area‚ away from direct sunlight and the IntelliChlor unit.
When adding salt‚ use only pool-grade salt and distribute it evenly throughout the pool. Avoid direct contact with salt‚ as it can cause irritation. Wear appropriate protective gear‚ like gloves and eye protection‚ when handling any pool chemicals. Refer to the Pentair manual for specific chemical compatibility guidelines.